Talk to us
  1. Home
  2. Hardware
  3. UTR3208

RTU for telecom

UTR3208

Every site under monitoring, without leaving the Operations Center.

The UTR3208 reads alarms and measurements at base stations, POPs and repeaters, executes remote commands and delivers everything to the SGI.

SNMP v2cModUTRModbus RTU−48 Vdc

Features

Status signals, measurements and remote commands in the same device.

The UTR3208 is installed at the site and connected to the equipment that matters: power, air conditioning, doors and sensors. It follows every signal and alerts the Operations Center when something changes.

From the Operations Center, the team can also command the site, with no trip needed to restart a device or test an alarm.

  • Status signalsIsolated digital inputs for site alarms and states.
  • Remote commandsRelay outputs to switch on, switch off and reset equipment remotely.
  • Remote measurementsAnalog inputs for temperature, voltage and other quantities.
  • Powered by the site itselfRuns on the −48 Vdc supply already available in telecom.
  • Web interface and Wi-FiConfiguration in the browser, over the network or through the Wi-Fi access point.
  • Firmware and backupFirmware updates and configuration backup through the web interface.

Main features

Built for the routine of telecom sites.

Full specifications, dimensions and diagrams in the datasheet, sent after sign-up.

The web interface shows the state of status signals, remote commands and measurements, and brings together the device configuration.

Inputs and outputs

  • 32 optocoupler-isolated digital inputs
  • 8 relay outputs, dry contact, monostable or bistable
  • 4 analog inputs, 4 to 20 mA or 0 to 5 Vdc

Communication

  • 10/100 Ethernet with SNMP v2c, private MIB and traps
  • ModUTR protocol, by ATI
  • RS485 with Modbus RTU for sensors, such as temperature
  • Wi-Fi as an access point for configuration

Installation

  • −48 Vdc power supply, positive grounded
  • Operation from −5 to +60 °C
SNMP v2cModUTRModbus RTUHTTP
Need fewer points?The UTR1608 is the same RTU built with fewer inputs, for smaller sites.
See UTR1608

How it works

From the site to the Operations Center.

The UTR3208 talks to the site equipment on one side and to the SGI on the other.

At the site

Equipment

  • Rectifiers and batteries
  • Air conditioning
  • Doors and sensors
  • Generator set
At the site

UTR3208

  • Reads alarms and measurements
  • Executes remote commands
  • Local web interface
At the Operations Center

SGI

  • SGI, ATI's telecom monitoring
  • Alarms by severity
  • Remote control and reports
Professional with a tablet in a telecommunications equipment room
UTR3208Fewer trips, more control over every site.

Applications

Where the UTR3208 works.

For operators, tower companies and telecom infrastructure providers.

  • Base stationsRadio base stations with site alarms, power and air conditioning followed remotely.
  • POPs and exchangesPoints of presence with doors, temperature and equipment under continuous monitoring.
  • RepeatersRemote sites, where every trip is expensive, operated from the Operations Center.
  • Site powerRectifiers, battery banks and generator set monitored, with remote control.

Works with

Part of ATI's telecom solution.

RTU and monitoring developed by ATI to work together.

Software

SGI

ATI's telecom monitoring receives data from the UTR3208 and brings all sites together on one platform.

Meet the SGI
Version with fewer points

UTR1608

The same RTU, built with fewer inputs, for smaller sites.

See UTR1608
Segment

Telecom

Monitoring, hardware and support for telecom sites, from a single supplier.

See Telecom

Frequently asked questions

What we are asked most about the UTR3208.

What is the difference between the UTR3208 and the UTR1608?

Both share the same base. The UTR1608 is built with fewer inputs, for sites with fewer points to monitor. Our engineering team recommends the right model for each site.

Does the UTR3208 come ready for the SGI?

Yes. The UTR3208 and the SGI are developed by ATI to work together: the RTU reads the site and delivers the data over SNMP or ModUTR, and the SGI organizes alarms, commands and reports.

Can I command site equipment remotely?

Yes. The relay outputs let you switch on, switch off and reset equipment from the Operations Center.

How is the UTR3208 configured?

Through the web interface, on the local network or through the device's Wi-Fi access point. The same interface lets you update the firmware and save a copy of the configuration.

Technical materials

Get the full UTR3208 datasheet.

Detailed specifications, dimensions and diagrams. We email it to you after a quick sign-up.

We use your data to send the material and, if you allow it, our newsletter, in line with the LGPD. Protected by reCAPTCHA: the Google Privacy Policy and Terms of Service apply.

Contact

Let's talk about your operation.

Tell us what you need. A specialist will reply with a proposal for your scenario.

Sales and technical support from people who know solar plants, energy storage and telecom.
ATIRua Paulo Freire de Araújo, 280, Estoril
Belo Horizonte, MG, Brazil · ZIP code 30494-280
We use your data only to reply to your message, in line with Brazil's data protection law (LGPD). Protected by reCAPTCHA: the Google Privacy Policy and Terms of Service apply.