EMS · Energy Management System

Every kWh in the right place, at the right time.

Control of BESS and hybrid plants without depending on each manufacturer's portal: time shifting, peak shaving, curtailment and voltage control, in an hour-by-hour schedule.

BESS Monitoring: active power, state of charge per rack and PCS modules (demo values)
EMS: dashboard with today's generation, PV power, boundary power, BESS state of charge and exported energy (demo values)

Overview

Storage and generation under the same strategy.

ATI's EMS controls storage and the plant without depending on each manufacturer's portal. The day's strategy is built hour by hour, with an explicit priority order instead of arbitration between functions.

Each function has its own safety limiters and only acts once it is enabled individually. This way the configuration is prepared and reviewed before it commands the equipment.

What an EMS is
Energy Management System: a system that decides, in real time, how much the BESS charges or discharges and how much the plant delivers to the grid, to carry out a strategy.
Time shifting
Store energy when it is worth less and use it when it is worth more, in charge and discharge windows.
Peak shaving
Shave demand peaks with the BESS, keeping boundary power below a limit.
Curtailment and Grid Zero
A limit on the energy exported at the point of connection. With the limit at zero, it is Grid Zero: the plant supplies consumption without exporting energy to the grid.

Highlights

Control with safety at every step.

Built to operate BESS and hybrid plants from different manufacturers with the same logic.

  • Multi-vendorReading and control without each vendor's portal.
  • Hour-by-hour scheduleOne function per hour, with explicit priority.
  • Safety interlocksState of charge and power limits for each function.
  • Simulation modeTest the strategy before commanding the BESS.
  • Curtailment and Grid ZeroExport at the point of connection under control, including zero.
  • Web interfaceConfiguration and follow-up in the browser.

Control functions

Four functions, each with its own limits.

How each function acts, what you configure and when to use it. In the charts, the dashed line is what would happen without the EMS and the blue line is what the EMS delivers.

  • TSTime shifting

    Stores energy when it is worth less and delivers it when it is worth more.

    How it works

    In the hourly schedule, you mark the charge and discharge windows. In the charge window, the EMS charges the BESS with the plant's generation or with grid energy. In the discharge window, it delivers the stored energy. Throughout the cycle, the state of charge and power limits remain in force.

    You define

    • Charge and discharge windows
    • Charge and discharge power
    • Minimum and maximum state of charge

    When to use

    Time-of-use tariffs and plants that want to move midday solar generation to peak hours.

  • PSPeak shaving

    Shaves demand peaks at the boundary using the BESS.

    How it works

    The EMS reads power at the boundary meter in real time. When demand exceeds the defined limit, the BESS discharges only what is needed to bring power back below the limit. Outside the peaks, the BESS recharges within the interlocks.

    You define

    • Demand limit at the boundary
    • Maximum discharge power
    • Minimum state of charge reserve

    When to use

    Sites that pay for contracted demand or face overruns during peak consumption hours.

  • CURTCurtailment and Grid Zero

    Controls how much energy goes out to the grid at the point of connection. With the limit at zero, it is Grid Zero.

    How it works

    The EMS compares exported power, measured at the point of connection, with the configured limit. When export tends to exceed the limit, the EMS lowers the generation power ceiling until it returns to the defined value, in real time. It is a single function: with a limit above zero, it is curtailment; with a zero limit, it is Grid Zero, and generation supplies only local consumption, without injecting energy into the grid.

    You define

    • Export limit at the point of connection, including zero
    • Hours when the limit applies
    • Power interlocks for the function

    When to use

    Curtailment: when grid access or the operator limits the plant's export. Grid Zero: when the site has its own generation and cannot or does not want to export energy.

  • V/QVoltage control

    Adjusts reactive power to support voltage at the point of connection.

    How it works

    In Q(V) curve mode, the EMS reads voltage at the boundary and commands the equipment's reactive power: with high voltage, it absorbs reactive power; with low voltage, it injects it. In fixed power factor mode, it holds the power factor at the defined value, whatever the generation.

    You define

    • Mode: Q(V) curve or fixed power factor
    • Voltage and reactive power curve points
    • Target power factor

    When to use

    Plants that must meet voltage and power factor requirements at the point of connection.

Each function has its own safety limiters and only starts acting once it is enabled individually.

Hourly schedule

The day's strategy, built hour by hour.

With scheduling enabled, the controller runs only the current hour's function. No functions competing for the same BESS.

  • SoC and power interlocksMinimum and maximum charge and power limits, always active.
  • Simulation modeThe strategy runs without commanding the equipment, for review.
  • Setpoint hold and reconnectionIf communication fails, the controller reconnects on its own.
  1. 00hTS
  2. 01hTS
  3. 02hTS
  4. 03h—
  5. 04h—
  6. 05h—
  7. 06h—
  8. 07h—
  9. 08h—
  10. 09h—
  11. 10hPS
  12. 11hPS
  13. 12hPS
  14. 13hCURT
  15. 14hCURT
  16. 15h—
  17. 16h—
  18. 17h—
  19. 18hTS
  20. 19hTS
  21. 20hTS
  22. 21hV/Q
  23. 22h—
  24. 23h—

TS Time shiftingPS Peak shavingCURT Curtailment and Grid ZeroV/Q Voltage control— No function

How it works

From the boundary meter to the BESS command.

The EMS Controller reads the plant's equipment, calculates the setpoint and commands the BESS. The SGD monitors everything, with the same login as the plants.

Field · any manufacturer

Equipment

  • PV inverters
  • BESS (PCS and BMS)
  • Boundary meter
  • Generators
At the plant

EMS Controller

  • Acquisition and logging
  • Functions and hourly schedule
  • Safety interlocks
In the cloud

SGD

  • BESS Monitoring
  • Alarms down to the component
  • Solar and BESS with the same login
Your operation

Team

  • Operations Center
  • Energy management
  • Field team
EMS Controller: metal enclosure with maintenance switch and indicator light on the door Inside the EMS Controller: ATI control unit, auxiliary logic, power supply with charger, battery and protections

Hardware · EMS Controller

The controller that runs the EMS at the plant.

A ready-to-install enclosure, with the ATI control unit, industrial switch, power supply with battery and protections.

  • Modbus TCP for inverters, BESS, meter and generators
  • Web interface: configuration and follow-up in the browser
  • Hourly schedule with 24 intervals
  • SoC and power interlocks, simulation mode
  • 100 to 240 Vac power supply, with internal battery
  • IP64 metal enclosure, with maintenance switch on the door
Modbus TCPHTTPIP64
Solar plant at dusk
EMSStorage and generation working together.

Who it is for

For those who have storage and want results from it.

Consumers, generators and operators who need to control demand, export and voltage.

  • Commercial and industrialDemand peaks shaved and energy used when it is worth the most.
  • Hybrid plantsSolar and BESS under the same strategy, with an export limit.
  • Utility scaleCurtailment and voltage control at the point of connection.
  • AgribusinessConsumption supplied by on-site generation, including with Grid Zero.

EMS module

Monitoring and control, two layers of one platform.

The EMS commands. BESS Monitoring shows the asset from portfolio to component, in the same registry and with the same login.

EMS module

BESS monitoring

System and per-rack state of charge, power, electrical measurements, PCS modules and alarms down to the component, from event to ticket.

See the module
Segment

Smart energy

Energy management for BESS and hybrid plants, integrating generation, storage, grid and consumption.

See the segment

Frequently asked questions

What we are asked most about the EMS.

What is the difference between an EMS and a SCADA?

A SCADA monitors: it shows measurements and alarms and sends commands when someone decides to. An EMS controls: every second it decides how much the BESS charges or discharges to carry out the defined strategy, such as peak shaving or an export limit. At ATI the two work together: the EMS controls and the SGD monitors.

Does the EMS work with BESS and inverters from any manufacturer?

Yes. The EMS reads and commands equipment over Modbus TCP, without depending on each vendor's portal. PV inverters, BESS (PCS and BMS), the boundary meter and generators all join the same strategy.

Can I test the configuration before commanding the equipment?

Yes. The EMS has a simulation mode, and each function only starts acting once it is enabled individually. The configuration can be prepared and reviewed before it takes effect.

What happens if communication with the BESS fails?

The controller retries the connection automatically and holds the last setpoint for a short interval. The state of charge and power interlocks remain in force.

Does the EMS do Grid Zero?

Yes. Grid Zero and curtailment are the same function in the EMS: it keeps the energy exported at the point of connection below the defined limit. With a zero limit, it is Grid Zero; with other values, it is curtailment. The same function also runs on ATI RTUs, monitored by the SGD.

Technical materials

Get the full EMS Controller datasheet.

Detailed specifications, dimensions and diagrams. We email it to you after a quick sign-up.

We use your data to send the material and, if you allow it, our newsletter, in line with the LGPD. Protected by reCAPTCHA: the Google Privacy Policy and Terms of Service apply.

Related solutions

Continue through your operation.

Solar

SGD

Cloud SCADA that brings plants and manufacturers together on one platform, with Grid Zero on ATI RTUs.

Meet the SGD
EMS module

BESS monitoring

From portfolio to battery rack, with the same login as your solar plants.

See the module
Segment

Solar

Software, hardware and services for solar plants, from the inverter to the Operations Center.

See Solar

Contact

Let's talk about your operation.

Tell us what you need. A specialist will reply with a proposal for your scenario.